testo 316-3 – leak detector for refrigerants
Highly sensitive universal leak detector for refrigerants
- High sensitivity - 4 g/a allows detection of the smallest leaks
- Detects all common refrigerants
- LED indication of leakage with simultaneous sound alarm
3 870:- exkl. moms
Finns i lager
Finns i lager
testo 316-3 – high sensitivity universal leak detector for refrigerants
A reliable refrigerant leak detector that should be part of every professional refrigeration technician’s equipment. It detects even the smallest leaks thanks to its high sensitivity of 4 g/a, and meets the requirements of the F-gas regulation as well as the SAE J1627 and EN14624 standards.
The instrument is ready for use immediately after switching on, without the need to select the characteristic curve. Thanks to the automatic reset, the testo 316-3 detects leaks even in rooms that have already been contaminated.
Quick overview benefits of the testo 316-3 leak detector
- Can detect all common refrigerants: CFCs, HFCs, FCs, etc.
- Highly sensitive (<4 g/a – 1 g/a according to the standard DIN EN14624:2012) – can detect even the smallest of leaks
- Ready for use – there is no need to select the refrigerant before start-up
- Automatic zero setting – can detect leaks in rooms that are already contaminated
- Visual and audible alarm activated when a leak is detected
- Quick and easy sensor replacement
- Meets the specifications of F-gas regulations, SAE standard J1627 and DIN EN 14624:2012 standard.
Included in delivery
testo 316-3 comes complete with sensor head, carrying case, factory protocol, batteries and filters
Fabriksprotokoll: utfärdas på fabriken efter en kontroll av att produkten fungerar och uppfyller angiven mätnoggrannhet. Läs om skillnaden mellan fabriksprotokoll och ackrediterad kalibrering.
Measurement parameter | g/a |
Sensitivity | 4 g/a (0.15 oz/a) |
Detectable gases | All HFC, HCFC and CFC gases e.g. FX80, I12A, R11, R114, R12, R123, R1234yf, R1234ze, R124, R125, R12a, R13, R134a, R13B1, R14, R142b, R161, R22, R227, R23, R236fa, R245fa, R32, R401A, R4 01B, R401C, R402B, R403B, R404A, R406A, R407A, R407B, R407C, R407D, R407F, R408A, R409A, R410A, R411A, R412A, R413A, R414B, R416A, R417A, R417B, R417 C, R420A, R421A, R421B, R422A, R422B, R422C, R422D, R424A, R426A, R427A, R434A, R437A, R438A, R448A, R449A, R452A, R500, R502, R503, R507, R508A, R508B, R1233zd, R450A, R455A, R 513A, R407H, R444B, R452B, R453a, R454A, R454B, R454C, R458A, SP22 |
Norms | SAE J1627, EN 14624, EC 2004/108/EC |
Operating temperature | -20...+50 °C |
Humidity during operation | 20...80% RH |
Storage temperature | -20...+50 °C |
Battery type | 2 x D |
Battery life | 16 hours of continuous operation |
Sensor lifetime | Approx. 80...100 hours (equivalent to approx. 1 year) |
Weight | Approx. 500 g (incl. batteries) |
Guarantee | 2 years |
Similar products
testo 316-4 – measurement set 1 for all common refrigerants
Leak detection of all common refrigerants
- Extremely high sensitivity of 3g/a allows detection of even the smallest leaks
- Light and sound alarms for optimum leak detection
- Earplugs for working in noisy environments