testo 835-T1 – IR thermometer with 4 point laser
IR temperature meter with small measuring area and 4-point laser
- Safe measurement at long distances thanks to 50:1 optics
- Clear 4-point laser sight shows exactly where to measure
- Combi instruments - non-contact IR measurement and contact measurement with sensors
3 565
testo 835-T1 – IR thermometer with small measuring surface and 4-point laser
The testo 835-T1 is the standard model of the 835 series, suitable for general temperature measurements with both non-contact IR technology and with standard probes for insertion and contact measurements. It ensures maximum safety and precision when measuring temperatures on small objects, even from considerable distances. Such as control measurements on specific wall or house sections, troubleshooting of heating and air conditioning systems, safety checks of electrical installations or quality control in various industrial processes.
You can also use the testo 835-T1 to log measurement values when connected to a PC via USB cable, thanks to the testo EasyClimate software. The picture shows curves of IR temperature values and temperature values from a connected type K thermocouple sensor.
A summary of the benefits:
- Safe measurement at long distances thanks to 50:1 optics
- Clear 4-point laser sight shows exactly where to measure
- Combi instruments – non-contact IR measurement and contact measurement with sensors
- Adjustable alarm limits
- Memory for measured values and locations, and data analysis on a PC
- Clear backlit display
Included in delivery
Delivered complete with battery, Swedish manual and factory protocol.
You can download the EasyClimate software for free from the Download tab above.
Fabriksprotokoll: utfärdas på fabriken efter en kontroll av att produkten fungerar och uppfyller angiven mätnoggrannhet. Läs om skillnaden mellan fabriksprotokoll och ackrediterad kalibrering.
| Measuring range IR | -30 ... +600°C |
| Accuracy IR | ±2.5 °C (-30.0...-20.1 °C ) ±1.5 °C (-20.0...-0.1 °C ) ±1.0 °C (+0.0...+99.9 °C ) ±1% of mv (rem. range ) |
| Resolution IR | 0.1°C |
| Measuring optics IR | 50:1 |
| External donor | Thermocouple type K (NiCr-Ni) |
| Measuring range external sensor | -50 ... +600°C |
| Accuracy external sensor | ±(0.5°C ±0.5% of m.v.) |
| Resolution external sensor | 0.1°C |
| Operating temperature | -20 ... +50°C |
| Storage temperature | -30 ... +50°C |
| Battery type | 3 batteries type AA (or via USB when connected to a PC) |
| Battery life | About 25 hours without laser and backlight Approx. 10 hours without backlight |
| Dimensions | 193x166x63 mm |
| Weight | 514 g |
| Guarantee | 2 years |
| Emission factor | 0.10 to 1.00 (0.01 steps) |
| Issue table | 20 storable values |
| Laser marker | to from |
| Memory | 200 measurement values storable |
| Alarm (Upper/Lower) | for IR temperature measurement for Thermocouple Measurement |
| Alarm signal | optical and audio |
Thermocouple probes type K
-

Air, surface and insertion sensors
1 605 Art.nr 0602 5093Sensor set to perform temperature measurements in many different applications- Sensor type: TE type K
- Measuring range: -50 ... +400°C (air sensor, dip/plug-in sensor) -50 ... +350°C (surface sensor)
- Accuracy: Class 1
- Sensor length: See technical data
- Diameter: See technical data
-

Plug-in sensor, robust with handle
735 Art.nr 0602 1293Versatile insertion sensor with robust construction and handle- Sensor type: TE type K
- Measuring range: -60 ... 400 °C
- Accuracy: Class 2
- Sensor length: 114 mm
- Diameter: 4 mm
-

Air sensor, robust with handle
980 Art.nr 0602 1793Robust sensor with handle suitable for measuring in air ducts- Sensor type: TE type K
- Measuring range: -60 ... 400 °C
- Accuracy: Class 2
- Sensor length: 115 mm
- Diameter: 4 mm
-

Doppgivare, thin with fast response time
1 255 Art.nr 0602 0493Versatile sensor with fast response time, for air and liquid- Sensor type: TE type K
- Measuring range: -60 ... 400 °C
- Accuracy: Class 2
- Sensor length: 123 mm
- Diameter: 1.5 mm
-

Dipping sensor, thin with fast response time 1000 °C
1 535 Art.nr 0602 0593Thin diameter with fast response time and flexible probe- Sensor type: TE type K
- Measuring range: -60 ... 1000 °C
- Accuracy: Class 1
- Sensor length: 300 mm
- Diameter: 1.5 mm
-

Surface sensor with rigid measuring tip
980 Art.nr 0602 1993Waterproof with flat measuring tip for flat surfaces- Sensor type: TE type K
- Measuring range: -60 ... 400 °C
- Accuracy: Class 2
- Sensor length: 115 mm
- Diameter: 5 mm
-

Surface sensor, angled with spring-loaded measuring tip
2 290 Art.nr 0602 0993Also suitable for measuring on uneven and curved surfaces- Sensor type: TE type K
- Measuring range: -60 ... 300 °C (briefly 500 °C)
- Accuracy: Class 2
- Sensor length: 80 + 50 mm
- Diameter: 12 mm
-

Surface sensor with rigid measuring tip +1000 °C
1 785 Art.nr 0602 0693Waterproof sensor with flat measuring tip for flat surfaces. Suitable for high temperatures.- Sensor type: TE type K
- Measuring range: -60 ... 1000 °C
- Accuracy: Class 1
- Sensor length: 150 mm
- Diameter: 2.5 mm
-

Publisher mini
840 Art.nr 0602 0092Used directly with instruments or as a spare measuring head for tube sensors 0602 4592- Sensor type: TE type K
- Measuring range: -60 ... 130 °C
- Accuracy: Class 2
-

Wire feeder PFA insulated 2 m
595 Art.nr 1390 0345Very thin and flexible sensor suitable for measuring in small volumes of liquid- Sensor type: TE type K
- Measuring range: -75 ... 250 °C
- Accuracy: Class 2
- Sensor length: 2000 mm
- Diameter: 0.08 mm
-

Plug-in sensor, thin with fast response time
1 750 Art.nr 0628 0026Waterproof sensor for measurements without visible measuring holes- Sensor type: TE type K
- Measuring range: -60 ... 250 °C
- Accuracy: Class 1
- Sensor length: 150 mm
- Diameter: 1 mm
-

Stainless steel plug-in sensor
1 245 Art.nr 0602 2292Waterproof sensor suitable for measurement in food- Sensor type: TE type K
- Measuring range: -60 ... 400 °C
- Accuracy: Class 2
- Sensor length: 125 mm
- Diameter: 4 mm
-

Push-in sensor without handle, Teflon insulated cable
995 Art.nr 0572 90012 meter Teflon insulated cable Tmax +220 °C- Sensor type: TE type K
- Measuring range: -40 ... 220 °C
- Accuracy: Class 1
- Sensor length: 60 mm
- Diameter: 3.6 mm
-

Plug-in sensor, fast with short probe
1 860 Art.nr 0602 2693Short plug-in sensor with handle and fast response time- Sensor type: TE type K
- Measuring range: -60 ... 800 °C
- Accuracy: Class 1
- Sensor length: See technical data
- Diameter: See technical data
-

Thermocouple wire PVC insulated 100 m
1 995 Art.nr A10K-100For self-built transducers buy to contact- Sensor type: TE type K
- Measuring range: -30 ... 105 ° C
- Accuracy: Class 2
- Sensor length: 10000 mm
- Diameter: 3 mm
-

Sensors for low temperatures
560 Art.nr 0602 5793Flexible measuring tip, 500 mm long, Ø 1,0 mm. Suitable for temperature measurement in e.g. liquid nitrogen, low temperature freezing down to -196°C. The connector can withstand temperatures from -30 to +110 °C. -

Insertion sensors for compost
2 750 Art.nr 0602 1250Long robust sensor specially developed for measuring in compost- Sensor type: TE type K
- Measuring range: -60 ... 400 °C
- Accuracy: Class 2
- Sensor length: 1250 mm
- Diameter: 8 mm
-

Surface sensor with magnet +170 °C
2 475 Art.nr 0602 4792For use on metal surfaces. Adhesive force approx: 20 N.- Sensor type: TE type K
- Measuring range: -50 ... 170 °C
- Accuracy: Class 2
- Sensor length: 35 mm
- Diameter: 20 mm
-

Surface sensor with magnet +400 °C
2 745 Art.nr 0602 4892For use on metal surfaces. Adhesive force approx: 10 N.- Sensor type: TE type K
- Measuring range: -50 ... 400 °C
- Accuracy: Class 2
- Sensor length: 75 mm
- Diameter: 21 mm
-

Surface sensor for pipes Ø 15-25 mm
1 045 Art.nr 0602 4692Transducer with handle for measuring on pipes with diameter 15-25 mm- Sensor type: TE type K
- Measuring range: -50 ... 100 °C (Briefly 130 °C)
- Accuracy: Class 2
-

Surface sensor for pipes Ø max 120 mm
735 Art.nr 0628 0020Velcro sensor for measuring on pipes with a maximum diameter of 120 mm- Sensor type: TE type K
- Measuring range: -60 ... 120 °C
- Accuracy: Class 2
- Sensor length: 395 mm
- Diameter: 20 mm
-

Wire sensor PVC insulated 5 m
295 Art.nr A10K-5,0-F11KXSuitable for measuring air temperature, measurements in refrigerators and water temperatures- Sensor type: TE type K
- Measuring range: -40 ... 105 °C
- Accuracy: Class 2
- Sensor length: 5000 mm
- Diameter: 3 mm
-

Wire sensor PVC insulated 1.5 m
230 Art.nr A10K-1,5-F11KXSuitable for measuring air temperature, measurements in refrigerators and water temperatures- Sensor type: TE type K
- Measuring range: -40 ... 105 °C
- Accuracy: Class 2
- Sensor length: 1500 mm
- Diameter: 3 mm
-

Double sensor, stainless steel and Teflon insulated cable
755 Art.nr 0628 7533Durable sensor suitable for harsher environments- Sensor type: TE type K
- Measuring range: -50 ... 250 °C
- Accuracy: Class 2
- Sensor length: 40 mm
- Diameter: 6 mm
-

Radiant heat sensor
5 520 Art.nr 0602 0743Used as part of the measurement of operational temperature- Sensor type: TE type K
- Measuring range: 0 ... 120 ° C
- Accuracy: Class 1
- Diameter: 150 mm
-

Thermocouple wire PVC insulated (by meter)
30 Art.nr A82KFor self-built transducers buy to contact- Sensor type: TE type K
- Measuring range: -30 ... 105 ° C
- Accuracy: Class 2
- Diameter: 3 mm
-

Wire sensor kapton insulated 1.5 m
275 Art.nr B08K-1,5-F11KXFlexible, thin sensor with fast response time. Suitable for air and surface temperature measurement.- Sensor type: TE type K
- Measuring range: -85 ... 285 °C
- Accuracy: Class 2
- Sensor length: 1500 mm
- Diameter: 0.6 mm
-

Wire sensor fiberglass insulated 5 m
450 Art.nr C09K-5,0-F11KXDurable sensor for temperatures up to +400 °C- Sensor type: TE type K
- Measuring range: -50 ... 400 °C
- Accuracy: Class 2
- Sensor length: 5000 mm
- Diameter: 1 mm
-

Thermocouple wire PVC insulated 25 m
575 Art.nr A10K-25For self-built transducers buy to contact- Sensor type: TE type K
- Measuring range: -30 ... 105 ° C
- Accuracy: Class 2
- Sensor length: 2500 mm
- Diameter: 3 mm
-

Double sensor, ground +1100 °C 1030 mm
850 Art.nr 0600 5893Rigid sensor suitable for measurement in high temperatures. ATTENTION! Normal plug, needs to be used with adapter.- Sensor type: TE type K
- Measuring range: -200 ... 1100 °C
- Accuracy: Class 1
- Sensor length: 1030 mm
- Diameter: 3 mm
-

Thermocouple wire PVC insulated 50 m
1 095 Art.nr A10K-50For self-built transducers buy to contact- Sensor type: TE type K
- Measuring range: -30 ... 105 ° C
- Accuracy: Class 2
- Sensor length: 5000 mm
- Diameter: 3 mm
-

Thermocouple wire fiberglass insulated 25 m
595 Art.nr C09K-25For self-built transducers buy to contact- Sensor type: TE type K
- Measuring range: -50 ... 400 ° C
- Accuracy: Class 2
- Sensor length: 2500 mm
- Diameter: 1 mm
-

Thermocouple wire glass fiber insulated 50 m
1 250 Art.nr C09K-50For self-built transducers buy to contact- Sensor type: TE type K
- Measuring range: -50 ... 400 ° C
- Accuracy: Class 2
- Sensor length: 5000 mm
- Diameter: 1 mm
-

Thermocouple wire fiberglass insulated 100 m
1 950 Art.nr C09K-100For self-built transducers buy to contact- Sensor type: TE type K
- Measuring range: -50 ... 400 ° C
- Accuracy: Class 2
- Sensor length: 10000 mm
- Diameter: 1 mm
-

Plug-in sensor with steel cable
850 Art.nr 1390 0460Durable grill sensor suitable for food. Steel cable Tmax +450 °C.- Sensor type: TE type K
- Measuring range: -30 ... 250 °C
- Accuracy: ±0.7 °C (-20 ... +70 °C), class 2 (other ranges)
- Sensor length: 100 mm
- Diameter: 3 mm
-

Double sensor, ground +1100 °C 500 mm
850 Art.nr 0600 5793Rigid sensor suitable for measurement in high temperatures. NOTE! Normal plug, needs to be used with adapter.- Sensor type: TE type K
- Measuring range: -200 to 1100 °C
- Accuracy: Class 1
- Sensor length: 500 mm
- Diameter: 3 mm
-

Push-in sensor with Teflon cable
730 Art.nr 1390 2100Flexible oven sensor, can be clamped in the oven door. Teflon insulated cable Tmax +450 °C.- Sensor type: TE type K
- Measuring range: -30 ... 250 °C
- Accuracy: Class 1
- Sensor length: 1500 mm
- Diameter: 1.5 mm
-

Surface sensor with spring-loaded measuring tip
1 885 Art.nr 0602 0393Also suitable for measuring on uneven and curved surfaces- Sensor type: TE type K
- Measuring range: -60 ... 300 °C (briefly 500 °C)
- Accuracy: Class 2
- Sensor length: 115 mm
- Diameter: 12 mm
-

Long immersion sensor with protection tube
1 505 Art.nr 0628 1292Waterproof and robust dip/insert sensor with metal protection tube. Suitable for temperature control of frying oil etc. -

Dip donor, flexible +1000 °C
460 Art.nr 0602 5792Thin sensor suitable for measurement in high temperatures- Sensor type: TE type K
- Measuring range: -40 ... 1000 °C
- Accuracy: Class 1
- Sensor length: 500 mm
- Diameter: 1.5 mm
-

Fiberglass insulated wire sensor 1500 mm
235 Art.nr 0602 0645For temperatures up to +400°C. -

Wire feeder fiberglass insulated 800 mm
305 Art.nr 0602 0644Durable sensor for temperatures up to +400 °C- Sensor type: TE type K
- Measuring range: -40 ... 400 °C
- Accuracy: Class 2
- Sensor length: 800 mm
- Diameter: 1.5 mm
-

Wire sensor Teflon insulated 30 mm
235 Art.nr 0602 0646Ideal for quick air temperature measurements- Sensor type: TE type K
- Measuring range: -50 ... 250°C
- Accuracy: Class 2
- Sensor length: 30 mm
- Diameter: 1.5 mm
-

Wire sensor Teflon insulated 2 m
950 Art.nr 1390 3125Durable sensor suitable for measurement in harsh environments. Stainless steel probe and Teflon insulated cable Tmax +250 °C- Sensor type: TE type K
- Measuring range: -100 ... 250 °C
- Accuracy: Class 1
- Sensor length: 2000 mm
- Diameter: 3 mm
-

Surface sensor for pipes Ø 5-65 mm
2 085 Art.nr 0602 4592Spring loaded sensor with interchangeable measuring head for pipe diameters 5-65 mm- Sensor type: TE type K
- Measuring range: -60 ... 130 °C (Briefly +280 °C)
- Accuracy: Class 2
-

Emission tape
1 050 Art.nr 0554 0051Tape (Teflon®) with determined emission factor 0.93. Used for IR temperature measurement of shiny surfaces that are difficult to measure. Can withstand temperatures up to +250 °C. Length: 10 meters. -

Silicone paste
98 Art.nr 0190 0030Thermally conductive silicone paste, 30 grams. For good heat transfer when measuring temperatures on surfaces or in immersion tubes. Maximum temperature: +260 °C. -

Extension cable 5 meters – TE type K (kopia)
375 Art.nr F11KX-5-F20KX5 meter extension cable for TE type K sensors. -

USB cable
95 Art.nr 0449 00472 meter cable for connection between measuring instrument and computer. USB standard connector and USB mini B connector. Equipped with a ferrite core at each end to reduce interference.
EasyClimate till testo 480 och testo 835. Om du redan har installerat EasyClimate på din PC kommer ditt befintliga program att uppdateras automatiskt.
(1) Kontrollera att firmware-versionen fortfarande är aktuell efter uppdatering av EasyClimate.
(2) Det här programmet har stöd för testo 480.
(3) Ta en säkerhetskopia av all din data innan du gör en om-installation eller en uppdatering.
[sc name="installationstips-windows-program"][/sc]
Similar products
testo 830-T4 – IR thermometer with small measuring area
Small area IR thermometer with a two-point laser
- Small measuring surface - measuring optics 30:1
- Clear 2-point laser sight.
- Combined instrument
testo 835-T2 – IR thermometer up to 1 500 °C
IR thermometer for non-contact measurement up to 1500 °C
- Measurement range up to 1500 °C
- Safe measurement at long distances thanks to 50:1 optics
- Clear 4-point laser sight shows exactly where to measure